9.02.2018

How to install MB Star Xentry Openshell on Windows 10

Xentry Openshell XDOS Windows 10 installation tips and guides for newbies:
– XDOS Windows 10 Startkey not valid
– XDOS Windows 10 security settings
– No Windows 7 VMware on Windows 10
– Windows 10 Ad-Hoc Fix
– Ad-Hoc connection on Windows 10
– Sdconnect C4 Wifi connection on Window 10
– 09.2018 XDOS Windows 10 reliable source
xentry-connect-xdos
In detail…
(Note that all solutions here are based on personal experience and you can have a try as you want, but no one will hold responsibilities of what will happen to your tool and car. Good luck!)

  1. XDOS Windows 10 Startkey not valid
I have strange problem with XDOS version on Win 10 x64In ConfigAssist I can’t enter Xentry key – “StartKey not valid error”
I try to use standalone key center but see 0x8000704C7 error when I start it.
For Win10x64, it is one of the recommended system requirements by Mercedes. but maybe there is some obstacle(s) but a member wrote in this thread that he could handle it as well.
Xentry xdos: xentry diagnosis for 12/24v using partd aka C3 (obsolete), sdconnect aka C4, ecom, xentry connect aka xentry kit 2, and bosch vci aka xentry kit 3
Xentry passthru EU or USA: xentry diagnosis using J2534 passthru devices e.g: mercedes passthru vci (12/24v), avdi, vas5054a (12v), drewtech MongoosePro (12/24v) and many other J2534 compatible devices.

  1. XDOS Windows 10 security settings
I have enough problems with w10 and security settings I just used w7 x86 ultimate went thru no problems did all my addones 1st took some time but , for some reason no taskbar icom for connection setup but can manually open .
if you install xentry passthru, it will not install sdconnect toolkit.
but if you install xentry xdos, the sdconnect toolkit will be installed.
you can set to ‘show’ in the taskbar tray at right bottom corner.

  1. No Windows 7 VMware on Windows 10
Are you booting into a Win7 VM or some sort of Win7 image on your Win10 laptop?
No VMware no win 7 image. It working on Windows 10 64bit professional. The same Ad-hoc like on Win 7. WEP is not problem. You have to manually set new connection with name Road24h/WEP/key uncheck automatic connection or something like this /I forgot/ then use solution which posted Mr.Rocinante and allow Ad-hoc thats all. This working for me. You can see on picture in my post how is connected SDConnect. I tested it on 3 cars and no problem with Ad-hoc. I reinstall full system now because I found one larger hdd

  1. Windows 10 Ad-Hoc Fix
On win 10 will be hard as hosted networks on win 10 not accept wep anymore
This is how I fixed the Win10 Ad-Hoc, wireless SDConnect C4 connection issue.
I downloaded the Win 8.1 wireless adapter drivers for my specific wireless card.
Download ONLY the drivers, not the software suite with the driver.
The Win 8.1 drivers will allow Ad-Hoc to function under Win 10.
I deleted/uninstalled my wireless adapter card to remove all current drivers associated with this wireless adapter.
I double clicked the .exe driver file for Win 8.1. The software found my wireless adapter and installed the Win 8.1 drivers.
Rebooted system, Ad-Hoc functions properly now.
Hope this works for others using Win 10.

  1. Ad-Hoc connection on Windows 10
There seems a problem between Ad-hoc and win 10?
This solution working but also need to be allowed Ad-hoc.
On the pictures you can see adhoc connection on win 10. You need settings from thread “sdconnect xdos configuration” you need set up new connection Road24h with wep encryption and allow adhoc that’s all.
xdos-xentry-windows-10-install-1
xdos-xentry-windows-10-install-2
xdos-xentry-windows-10-install-3
  1. Sdconnect C4 Wifi connection on Window 10
Can somebody help me with wifi connection C4 and win 10 
It worked for me
To save an ad-hoc network and its network key on the guest computer (running Windows 7)
Note down the SSID, security type, encryption type and the key of the ad-hoc network.
Disconnect your connection to any wireless network and switch off/disable your wireless device. Turn on/enable your wireless device but don’t connect to any network. (Thanks GK.)
Click on the network icon in the taskbar.
Click Open Network and Sharing Center > Manage Wireless Networks > Add.
Click “Manually create a network profile”. (This may look silly but we really are going to create an infrastructure network now.)
Enter the network name (SSID), security type, encryption type (if any) and the key that you noted in step 1.
Uncheck both checkboxes (“Start this connection automatically” and “Connect even if the network is not broadcasting”.) [Note that you cannot have the connection start automatically. If you try to have it checked, step 10 will fail. A different way to start it automatically during system boot is described below.]
Click Next > Close. Your connection must appear in the list with the icon suggesting infrastructure (two big screens connected to a tube). Don’t worry about it.
Click Start, type in “cmd” in the search box, press Enter.
In the Command Prompt, type in “netsh wlan set profileparameter name=NetworkName ConnectionType=IBSS”, exactly as shown, without quotes, except you must substitute NetworkName with the SSID (network name) of your ad-hoc network.
If everything went well, you’ll see that the icon has now changed to an ad-hoc icon (three small screens connected to each other) in the Manage Wireless Networks window.
Turn on/enable your wireless device, and try connecting to the Ad-hoc network. You will notice that you no longer need to enter the network key.
To automatically connect to a saved ad-hoc network during Windows boot (can be applied to both guest and host computers running Windows 7)
Click Start > point to All Programs > right-click Startup > click Open. (You may choose Open All Users instead if you prefer).
Right-click an empty space and click New > Shortcut.
Type in “netsh wlan connect NetworkName”. Once again, NetworkName must be substituted with the SSID of your ad-hoc network.
Click Next and enter a fancy name such as “Connect to NetworkName” or something like that.
Click Finish and you’re done. This shortcut will run when Windows starts up, giving you a very brief flash of the black command window, followed by your computer connecting to the ad-hoc network if it is available. Tip: You can also pin the shortcut in your taskbar or copy it to the desktop to easily connect to the network any time you want.
Note: You will probably need Administrator access to complete some of the steps above (in both procedures).

  1. 2018 XDOS Windows 10 reliable source
Do you have any reliable link for 09.2018 Xentry? Better have been confirmed to work no issues with SDconnect?
I’m using the site http://www.obdii365.com/wholesale/201809-mb-sd-connect-compact-c4-software-ssd.html good tech support. Free activation help via remote
Upload images…
2018-09-xentry-xdos-1
2018-09-xentry-xdos-2
2018-09-xentry-xdos-3

2018-09-xentry-xdos-4

2018-09-xentry-xdos-5

7.10.2018

07.2018 Xentry OpenShell Download + How to Install

Mb Star diagnostic 07.2018 Xentry OpenShell XDOS download with security:
2018-07-xentry-openshell-1
2018-07-xentry-openshell-2
2018-07-xentry-openshell-3
2018-07-xentry-openshell-4
100% tested and confirmed

07.2018 XDOS Windows 7 Windows 10 Install:

– 07.2018 Xentry/DAS Windows 7 FAQs:

  1. Try install win7 x86?
Install it on win 7 64 Bit or remove the package.

  1. I can try install win7 x86 but not complete. I have error 393. part gives error. How to solution.
try install at fresh windows SP1 also disable UAC..

  1. Have Communication Error 1.53315.9999 on win7 x86 pro. How to solve
everything fine with me, but make sure of the IP, try to do the MUX firmware again and report

– 07.2018 Xentry/DAS Windows 10 FAQs:

  1. Xentry 07.2018 on windows 10?
today i installed at windows 10 64bit. windows download form microsoft site. before installation i stop windows auto update and disable UAC. firewall. defender. everything work good…

  1. I counted a problem after installing 7/2018 on my Windows 10 64bit:
    “Communication Error 1.53315.9999 – Initialization of the multiplexer has failed”
    The XDOS doesn’t see Ignition-On signal.
Ps. Before I used 03/2018 without any problem.
2018-07-xentry-openshell-communication-error

how did you install 7.18 ? did you uninstall 3.18 and install 7.18?
most probably your problem is windows issue, specially windows 10
I suggest you try your mux on other system first and report

– 07.2018 Xentry/DAS errors and solutions:

  1. Xentry.exe application error?
2018-07-xentry-openshell-application-error
restart and try again, check your memory as well
stop windows defender and UAC
make sure you don’t have viruses
stop antivirus
check if there is any software consuming the memory
check disk usage if it is always 100% in you windows 10 then google its solution which is available online
and if you can do diagnostic for your RAM do that from your laptop

  1. Anyone the missing akktab.csv pkw file for 2018.07 ?
03.2018 akttab for 07.2018 offline coding:


  1. After updating the MB SD Connect C4 MUX firmware I got the cal error 870.
    It seems that the new version has blocked my MUX, even I have applied the blacklisted fix before!!!
Use correct lic.sli and Problem is gone.

  1. Installed this version but when doing a forced regeneration when asked to start engine I am loosing connection with multiplexer?
update full addons and try again

  1. I need Hht diagnostic. Hht only working x86. I can try xentry sim test 212 and 204 not complete. Not working xentry sim. How to solution error. Please help me.
2018-07-xentry-openshell-error
Just finished x32 installation for HHTwin and no problem.


Categories
Hardware
Software
Forms

Keywords
Software Support

Change log
Release Notes 07/2018
  1. New features of XENTRY Diagnosis Kit 3 systems
New features in Support Tool:
The Support Tool has been given a new icon in a new design.
The “Contact Support” tab contains the email address for the User Help Desk.
The “Support Packages” tab has a “Pin icon” located at the left next to each screenshot. When you
click on the button, the Screenshot Tool marking window appears.
Screenshot Tool: After closing the marking screen, the selection screen for the Screenshot Tool
appears. This makes it easier to create several screenshots than was previously the case.
A graphic set of instructions before the test is available in “VCI self-diagnosis”.
“Network self-diagnosis” shows adapter settings and network settings and a connection check is also
run.
“XENTRY Diagnosis Pad” tab: System information displays the connection status to the backend
servers in the form of an immediate status picture.
The “Client test” button in the “Information” is no longer shown, it is now available as bandwidth selfdiagnosis.
The new overview page in the “XENTRY Diagnosis Pad” shows a summarized view of all the relevant system information.

New features in XENTRY Update Service:
If Retail Data Storage malfunctions because of a defect, ConfigAssist can be used to configure the
“RDS failure” fall-back mode. In this mode the data are loaded directly by the XENTRY Diagnosis Pad
from the Internet. Important note: Please coordinate this in advance with your IT manager!
Connected XENTRY Kit I Kit 2 systems are now visible in the XENTRY Update Service Control
Center in Device Administration
The flashware user interface does not contain any details on Regio or the type of Digital Operator’s
Manual, the HLI information is no longer available

New feature of XENTRY Diagnosis VCI:
The WLAN channel for XENTRY Diagnosis VCI can be configured.
Important: This setting is only to be used when the VCI connection has problems!


  1. Data storage media
1 Blu-ray Disc for XENTRY Diagnosis Software for XENTRY Diagnosis Kit 3
1 Blu-ray disc for XENTRY Kit I Kit 2 Update
Telematics and Regio-DVDs, if applicable

Passenger cars:
The following telematics CDs/DVDs are still required (item numbers, market-dependent, plus any special provisions):
1668270859-0001 1718270100-0001 2168274159-0001
1668271300-0001 1718274459-0001 2218270065-0001
1668273900-0001 1978270400-0001 2218270100-0001
1668274600-0001 2048271000-0001 2218270465-0001
1668274700-0001 2128271900-0001 2218270665-0001

Vans:
The following telematics CDs are still required (item numbers):
1668273500-0001
6398271159-0001
6398271259-0001


Changes since the last release
New documents
No entries available
Updated documents
Installing and configuring XDOS with VCI
User manual XENTRY Diagnostics Open Shell Variants
Help Card XENTRY Diagnosis VCI



6.29.2018

MB Star DAS SCN Coding Cannot be Carried Out Solution

Here's working solution to MB Star diagnostic software online SCN coding failed to carry out problem which happened all around the world these days.



Error:

Error in XENTRY

Data transfer has failed (DAS <-> XENTRY)

Possible cause and remedy:

- Incorrect data were received.

- Unknown command or incorrect data in command

Do you went to repeat this procedure?

xentry-error-data-transfer-failed

Error in DAS

The coding could not be caned out (CAL_Comm_Error)

Fault 8.561.6113

The coding may be wrong. (00001)

SCN coding must be carried out again.

If the problem persists, please contact the User Help Desk .
das-coding-cannot-carry-out


Solution:
Go to  C:\programm files\mecredez-benz\addons centerxx
Change folder name "addons centerxx" to "addons center" (delete "XX" letters)
Restart the computer 
Run c:\programm files\mecredez-benz\addons center\addonscenter.exe
It will run auto update with network connection .


6.21.2018

How to install MB HHT-WIN on Windows 7 with XP Mode

Today, I’ll chip in some words with Windows 7 (XP Mode) installation of HHT – Hand Held Tester for Mercedes mb star diagnostic with SD connect C4 or Part D (C3).

Here you go.

How to add HHT shortcuts to All Users Folder in Windows XP 

  1. With the Windows XP Virtual Machine running, right-click on the Windows XP Start button.
mb-star-hht-win-on-win7-xp-mode-1
  1. Click Open All Users from the list.

  1. When the All Users window appears you will be able to copy and paste or drag shortcut icons from the Windows XP Start Menu to the All Users window. The same applies to application shortcuts on the Desktop and in other locations. The key to this tip is making sure that the shortcuts are saved in the All Users Start Menu folder.

  1. Close the Windows XP virtual machine.


How to copy HHT shortcuts of Windows XP Mode Applications to DAS\BIN:

Once the applications in Windows XP have been added to the All Users folder, Windows 7 Start Menu should be updated to include those shortcuts. Follow the instructions below to copy hht shortcuts to DAS\BIN

  1. In Windows 7 click on the Windows Orb to open the Start Menu.

mb-star-hht-win-on-win7-xp-mode-2

  1. Click All Programs to view the list of applications.

  1. Scroll down the list and click on Windows Virtual PC.

  1. You should see a folder in this directory named Windows XP Mode Applications, click on it.

  1. A list of Windows XP Mode applications (HHT) shortcuts will appear. Copy those shortcuts to DAS\BIN. Also copy files: hhtwin_vm_start.exe, , hhtwin_vm_start_pkw.bat, hhtwin_vm_start_nfz.ps1.

mb-star-hht-win-on-win7-xp-mode-3
mb-star-hht-win-on-win7-xp-mode-4

How to setup MB HTT software language:

you navigate to

C:\…\HHTwin.ini

parameters:
SPC=02
SPCN=02
SPCP=02
SPCD=02
SPCV=02

change to:
SPC=XX
SPCN=XX
SPCP=XX
SPCD=XX
SPCV=XX


or added to hhtpkw shortcut the language parameter (-L) e.g:

C:\HHT\PKW\HHTPKW.EXE -Lxx



where XX is:

00 = german
02 = english (british)
03 = french
04 = spanish
05 = portuguese
06 = italian
07 = dutch
08 = danish
09 = swedish
010 = finnish
012 = greek
013 = english (american)
017 = turkish
018 = polish
019 = czech
020 = japanese
021 = hungarian
022 = russian
023 = korean
025 = chinese
026 = romanian
027 = serbian

Attachment: HHT-WIN on Windows 7 64 bit
hht-win-on-win7
http://blog.obdii365.com/2018/06/21/set-up-mb-hht-win-software-on-windows-7/

3.21.2018

How to install 2017.12 XENTRY PassThru

Free download XENTRY Diagnostics EU & USA PassThru 2017-12
(thanks to cyburbia for the source)

What is Xentry Passthru:
Xentry Passthru is different from from regular Xentry openshell. Xentry passthru does not use SDconnect toolkit. When you launch the program it will give you a dropdown where you can choose which J2534 device (can be found at http://www.obdii365.com/) you want to use.

How to install XD PassThru 2017-12:
1. prepare windows sp1 x86 or x64
2. run setup.exe
3. copy xentry missing pictures
4. install block check keys to daimler server
5. install old key loader for configassist
6. install 2221-45 error fix
7. install 3.91 error fix
8. install das license 0 day fix
9. install passthru device driver
Do not need:
1. 32 Bit Installer fix
2. xentry and das blacklist
3. scn fix (i’m not sure)

Vehicles which are not supported in DAS:
– Bharat Benz
– Foton
– Fuso
– LKW
– IMO
– Unimog
– PKW HHT

XDPT system and data version
xdpt-data

XDPT
xdpt
FAQs – XENTRY PassThru installation tips:

Q: This and all PassTru versions works as good and as same as SD Connect C4 units?
A: – for Xentry, i check all diag files are identical with open shell.
– for DAS, it is not as complete as openshell with sd4. see note above.
passthru limited to obd2 vehicles only, pkw,transp, smart.
– passthru device can’t be used with v-ediamo and dts monaco.

Q: Is the full install file or just update file?
A: I think is full, is 21,3GB

Q: Will this version work for SCN Coding ?
A: yes, it should be. please try and give feedback.

Q: Need help with install.
4. install block check keys to daimler server
5. install old key loader for configassist
6. install 2221-45 error fix
7. install 3.91 error fix
8. install das license 0 day fix
9. install passthru device driver
A: 4. install block check keys to daimler server
edit C:\Windows\System32\drivers\etc\hosts
Code:
127.0.0.1       openshell.aftersales.daimler.com
::1             openshell.aftersales.daimler.com

or use this
edit appserv.ini in
program files (xxx)\mercedes-benz\appserv\appserv.ini
[301]
name=zbus
url=https://localhost

Q: I like to know, this is pass thru version is there a other version for diagnose for pass thru device???
so 1 dvd diagnose other dvd for programming?
A: only 1 dvd mate. Sdflash folder for programming is include in it.
the using of xentry passthru version is like the xentry open shell version only it is using passthru devices.

Q: Could you explain this a little more please? “4. install block check keys to daimler server”
A: from old crack:

Code:
C:\Program Files\Mercedes-Benz\xentry\fusoko\eclipse\plugins\
Rename File
From
com.daimler.xentry.diagservice_1.6.0.201608011018.jar
To
com.daimler.xentry.diagservice_1.6.0.201608011018.jar.DELETE
now its other version number
also block starkey center
host file:

Code:
127.0.0.1       openshell.aftersales.daimler.com
::1             openshell.aftersales.daimler.com

Ps, Credited to the contributor and participants in the thread from http://mhhauto.com/


http://blog.obdii365.com/2018/03/21/12-2017-xentry-passthru-download-free/

11.26.2017

2017 DoIP Xentry Connect C5 Testing Working

Real DoIP Xentry Connect C5 came as the newest star diagnosis system in the year 2017. it’s 1:1 clone of the original. Same as the one produced by French ACTIA Company, can test Engine /Transmission / air conditioning /SRS.ABS/ anti-theft system and OBD-II system, for basic diagnostic, SCN coding & ECU programming.

xentry-connect-c5
Whats new? & what is updated, compared with sdconnect c4?


1 This SDconnect C5 is the real version with HQ PCB like the original, not the cheap one made by SD connect PCB.
(attach PCB photos in the last part)

2 support the newest hybrid W222.

3 has an Ethernet switch, which switches the TCP/IP messages in the event of DoIP diagnosis to the vehicle side.
Electrical InterfaceSD Connect C4Xentry connect C5
K-LINEyesyes
CANyesyes
DOIPnoyes

4 has a qualitative improvement in hardware and software by authorization of diagnostic interface to control the software.

Hardware: The hardware of C5 is better and stable than SDconnect C4
1.OS: Windows Embedded Standard 7(32bit)
2.Processor: ArrandaieCeleron P4500 oder P4505(38W TDP)
3.Memory: 4G hard disk with 256GB SSD
4.Display: 128*64 PX
5.Battery: 40 minutes (When CPU capacity to 60%)
6.Weight: 1.9KG
7.Network connection: WLAN : IEEE802.11 a/b/g/n2.4+5GHZ
The way to connect: support wireless connection via 1000M workshop switches, also support wired connection.

Software: All Mercedes diagnostic software 2017.9 is loaded into the Xentry Connect multiplexer itself.
The management software can be installed on any computer with Windows 7 – 32-bit or Windows 8 – 32-bit and serves only for communication with the multiplexer

The licensing system is reworked – now licenses are stored on MB servers – Any license changes are tracked by the multiplexer when connected to the Internet network.

5 at a lower price: the 1:1 clone of the original C5 is much more cheaper than that from the ACTIA Company

Undoubtedly, the original c5 with Panasonic tablet from the ACTIA Company is excellent … But … Its price is disheartening. The cost of the Japanese tablet is realistic to buy pieces of eight new laptops or tablets from other manufacturers.

So , recommend buying an original Xentry connect and 1:1 clone: http://www.obdii365.com/wholesale/wifi-mercedes-benz-c5-sd-connect.html (it’s 1259 usd, the same result as the original), then buy a laptop yourself . the software from which Xentry Connect is managed can be installed without any problems on any computer that has a 32-bit version of Windows 7, Windows 8 or Windows 10. It’s clear with Xentry Connect itself – there’s no alternative .


Attachment: Xentry Connect C5 PCB- real & fake

PCB from real DoIP Xentry Connect C5
xentry-connect-c5-pcb-1
xentry-connect-c5-pcb-2
xentry-connect-c5-pcb-3

xentry-connect-c5-pcb-4

xentry-connect-c5-pcb-5
This board is verified to work no issues.
xentry-connect-c5-testing-1
xentry-connect-c5-testing-2
xentry-connect-c5-testing-3
xentry-connect-c5-testing-4
PCB from fake SD Connect C5 (actual SD Connect C4 in C5 case)
sd-connect-c5-pcb-1

sd-connect-c5-pcb-2

sd-connect-c5-pcb-3

the fake mb star c5 has nothing update
it is another SD connect c4 with a different look only
fake C5 adopts the same design in appearance as the genuine from French ACTIA Company
same sw, some PCB, same result as SDconnect

So,  Why you should buy Xentry connect?

After 2015, all Star Diagnosis equipment is no longer supported. First of all, this means that there is no update of the diagnostic data for the newest cars and their systems, as well as the lack of the possibility of coding and programming of electronic units due to the backlog of the software data level in the device, from data in the electronic control units of the car.

Already at the end of 2014, at most dealerships, almost all of the previously used Star Diagnosis Compact4 with SDConnect DoIP multiplexers were almost completely removed. Instead, dealers received Xentry Kit kits, which include the latest Xentry Connect multiplexers and Xentry Tab tablets from Panasonic. Tablets are custom-made, although they also have a “civilian” version – the Panasonic Toughbook CF-D1, somewhat inferior in terms of battery life to the original Xentry Tab, but it has a much more powerful configuration.
www.obdii365.com