6.28.2021

Xentry Connect C5 vs. MB SD C4 or C5

 Mercedes Benz MB Star diagnosis system Xentry Connect C5 and SD Connect C4/C5 which is better? Check user feedback below:

xentry-connect-c5-or-sd-connect-c4

*The feedback was based on who has both xentry connect and sdconnect systems.

*C5  is actually another case in SD C4 (normal C4, not DoIP one).

 

SDConnect Pros:

simple to work interface

uses less obd 12v power

lighter

better internet speed while interface is connected

more flexible for playing with soft like dts or vediamo

compatible with latest software, SDconnect now works with 2021/06 (in June 2021).

 

 

SDConnect Cons:

software is on your laptop and if you are not tech savy there is a big possibility you delete something or your key stops working

 

 

Xentry Connect Goods:

almost all software is installed on interface’s ssd
less chance software is going to break or get virused

 

 

Xentry Connect Nagatives:

does not support new software, the last SW its from 2020/06

harder to work with when you are setting up everything at the beggining like license, updates etc., easy after everything is setup
uses more power from obd 12v
heavier
internet speed is slower when using this interface

 

 

 

Recommendation:

If you have SD C4 DoIP it is better than XC (Xentry Connect). XC is so slow even after upgrade. If you have good PC, XDOS is much faster.  even though sdconnect interface is older than xentry connect, it is still supported even to 2021.06 version, while xentry connect xentry versions stopped at 2020.06.

XC don’t have problem with HHT, normal XDOS (win10 64bit) needs virtual machine etc.

 

 

 

MB SD C4 DoIP wifi

Adds heat sink to improve the heat dissipation effect of the host to make MB DOIP XC4 PLUS work more stably.

mb-sd-c4-doip-pcb-1

mb-sd-c4-doip-pcb-2

 

http://blog.obdii365.com/2021/06/28/xentry-connect-c5-and-sdconnect-c4-c5-which-to-buy/

5.18.2021

How to Repair 2021.3 MB SD C4 DoIP SSD Windows System?

I ordered a DOIP MB SD C4 PLUS with software xentry 2021.3 and was able to use this hard drive for 2 hours then it crashes. I was told me to change Bios to ACHI . That did nothing.

2021-03-mb-sd-c4-sdd-1

 

obdii365.com engineer replied:

Please refer to the following operation steps to fix your system.

 

First start your PC and press the power button while it tries to load the windows to force it to shutdown, do this three times in a row to get the automatic repair screen.

You could also disconnect it from the outlet, click on advanced options.

2021-03-mb-sd-c4-sdd- change Bios to ACHI 1

2021-03-mb-sd-c4-sdd- change Bios to ACHI 2

Click on troubleshoot.

2021-03-mb-sd-c4-sdd- change Bios to ACHI 3

 

Click on advanced options.

2021-03-mb-sd-c4-sdd- change Bios to ACHI 10

 

Click on command prompt.

2021-03-mb-sd-c4-sdd- change Bios to ACHI 11

 

Type in your password, and if you don’t have one just press continue.

2021-03-mb-sd-c4-sdd- change Bios to ACHI 12

 

Now type BOOTREC / FIXMBR and then press enter.

 

Type BOOTREC / FIXBOOT and then press enter.

 

If you get access denied, type the following command and then try again.

 

Type: BOOTREC / FIXBOOT and then press enter.

 

Type: BCDEDIT /EXPORT C:\ BCDBACKUP and then press enter.

 

Type: ATTRIB C:\BOOT\BCD -H -R -S and then press enter.

 

Type: REN C:\BOOT\BCD BCD.OLD and then press enter.

 

Type: BOOTREC / REBUILDBCD and then press enter..

 

Type: Y and then press enter.

Type Exit and then press enter

2021-03-mb-sd-c4-sdd- change Bios to ACHI 13

2021-03-mb-sd-c4-sdd- change Bios to ACHI 14

Press continue to restart.

2021-03-mb-sd-c4-sdd- change Bios to ACHI 15

 

Using tips:

Alright, if not lucky to repair by following the above method, you can find a USB flash drive to make the system boot, if you have a USB flash drive, contact at obdii365.com engineer who can make a USB flash drive for you remotely by teamviewer, then you follow the above operation to repair your system.

After I make a USB flash drive for you, you can insert the USB flash drive into the computer that cannot start, and then enter the PE system to repair it.

 

Alright, this is how to repair the windows system for DOIP MB SD C4 PLUS with SSD software 2021.3.

5.11.2021

MB SD C4 Blacklist Patch for S/N 101044

 Problem:

I have an issue with MB SD Connect C4 multiplexer (the old c4 i bought several years ago) with 03/2021 xentry.

It can access a C205. But failed to log in a C206 C220 d mod.206.016 year 2019 and a GLC254 300 4MATIC mod.254.147 year 2019.

xentry-login-failed

Possible reason and solution:

1.MB SD C4 Serial number 101044 was blacklisted.  It has problem using latest xentry.

2. SDConnect C4 firmware too old to support newer Mercedes benz. Borrow or purchase a newer MB SD C4 DoIP or MB SD C5 device.

3. Some blacklists can be bypassed by software.  Download the C4 blacklist patch, unlock serial number and try again. If don’t know how to unlock, contact our engineer via Teamviewer (your order number and device serial number are required to get the technical support.)

 

Free download C4 Blacklist Patch for S/N 101044

For serial number 101044 only.

mb-sd-c4-serial-number-101044
http://blog.obdii365.com/2021/05/11/free-download-mb-sd-c4-blacklist-patch/

4.14.2021

MB SD C4 Xentry 2021.3 Unknown Lan ID Solution

 When activating mb sdconnect C4 Xentry 2021.3, it shows ” Unknown Lan ID”, obdii365.com engineer offer the working solution.

mb-sd-c4-xentry-unknown-lan-id

Image 1: Xentry 2021.3 Unknown Lan ID

 

Solution:

  1. Start -> Execute -> cmd
  2. Enter: set devmgr_show_nonpresent_devices=12

Enter: set devmgr_show_nonpresent_devices=1

  1. Enter: start devmgmt.msc
  2. Click on [View] and select “Show hidden devices”
  3. Network adapters

Do not delete “RAS Async Adapter”, just delete the other gray options.

 

Alright, Xentry 2021.3 is working now with mb sdconnect C4.

3.29.2021

How to Get SDConnect C4/C5 to Work Under Part W?

 MB Star diagnosis SDConnect C5 Clone (its a C4 in a C5 shell) – It works great in Xentry, connects and are fast and never fails there.

Windows 7 32 bit Ultimate Activated – Works perfectly as well and are fully updated
240gb SSD
Vediamo 4.2.2 with a good license and everything activated.
SDConnect Toolkit 2.1.13.

 

My question is: How to get Vediamo 4.2.2 to run on Part W configuration without the ToolkitApiDll.dll error and vediamo not finding your SDConnect c4/c5? Vediamo 4.2.2 has the Part W-SDconnect functionality integrated, yet when I try to use it stops detecting the SDConnect, because Vediamo doesn’t seem to want to communicate. It is not a computer to ecu error, it’s simply a computer-software error.

 

Simple question: how to get the SDConnect to work under Part W – SDConnect
And I mean Part W and not Part P-eCom.

 

Look at this image:

mb-sd-c4-c5-under-part-w

2.1.30 SDConnect Toolkit and Dietrih’s Vediamo 4.02.02 works with part W. Just gotta try with Me21.cbf now and see if we cannot simply get vediamo to work with this “Too old” ECU.

 

Update:

Success to connecting to the ECU now! It can read fault codes, see sensor data and some more stuff. Not really been giving me in to change anything yet because I am not sure what to do yet. But this is a great step forward!

 

Enjoy!

 

For any question on SDConnect C5, contact at www.obdii365.com for

assistance.

3.25.2021

Tips on Sdconnect C4 WIS EPC activation

 I have mb Sdconnect C4 to activate code for WIS, EPC, xentry and dts Monaco, and then contacted obdii365.com engineer and they said ” You can send the activation id to calculate the password, or send it to teamviewer to activate the software for you remotely”, then they connected with teamviewer for Activation code for WIS and EPC, but for some reason hardware id changed (Lan Id is different. Probably because WiFi is on) and then Xentry doesn’t start.

wis-epc-activation

 

obdii365.com engineer replied me:

Follow the steps below;

  1. Delete the lic-key2.dat file under the C drive directory

(C:/Programdata/LicDir)

  1. The activation code of xentry is still deactivated by the one given to you before, and then a new lic-key2.dat will be generated under the C drive directory (C:/Programdata/LicDir)
  2. Copy a copy of lic-key2.dat, change the copy to a lic-key2.x4711 file, and then set the file attribute to read-only

 

Update!

Everything ok now. Xentry,Wis and Epc starts. Know i have to test the Sd connect C4 to a car.

 

Many thanks for their professional after-sale service.

3.16.2021

MB SD C4 EWA Local Host Cannot be reached

 Problem:

I tried to enter local host in MB SD Connect C4 EWA software program, it failed me and reported error "This site cannot be reached"

mb sd c4 ews This site cannot be reached 1
Solution:
Press windows icon on the tool bar. Find EWA program
Right click to open EWA as administrator 
Then Started EWA server 
It will show online status if it is working.
mb sd c4 ews This site cannot be reached 2

mb sd c4 ews This site cannot be reached 3

mb sd c4 ews This site cannot be reached 4

mb sd c4 ews This site cannot be reached 5

www.obdii365.com