5.15.2016

MB SD Connect C4 failed to work Tourismo bus (fixed)

SD connect c4 cannot power on when connected with Mercedes Tourismo bus? Mb star c3 get communication error also when connected to Tourismo? Here’s the customer solution of Mercedes Tourismo bus diagnosis or programming.

Multiplexer complaints:
“I have tried 2 different sd connect c4 on Tourismo buses and sd connect does not power on.
In the meantime those MB sd connect C4 works normally to any other MB Truck and car.
also on Tourismo have check MB Star C3 and works normally.”

Device used:
SD connect c4

You should check:
bus with OBD
pin 4 + 5
both must be connected and ground
In SDConnect “-” is 5 pin only. There is 4 contact not used in 16pin OBD connector.


Communication complaints:
“i’m getting an communication error when connecting xentry to a Mercedes tourismo.”
Tourismo-bus-communication-error-1



Tourismo-bus-communication-error-2
Tourismo-bus-communication-error-3
Device used:
Mb Star c3 multiplexer

You can try:
– turn OFF/ON BUS ground switch (our remove battery – cable). FPS1 wake up and Star diagnostic recognized FPS1/VIN code.
or
– enter the DAS ATEGO truck come and place manually and then it will work perfect


Coding complaints:
“Currently the speed limit is set to 100 km/h. I’m trying to set it to higher value (with DAS using modified EOL files). On the menu it tells me that I can, because there are higher values (105 km/h. 112 km/h, etc). But when I try to set the speed limit to higher than 100 km/h it doesn’t allow me to do it (can’t save the changes). When I try to set it below 100 km/h everything goes fine.

Device used:
MB SD C4 mux

You should:
Access special settings